Home › Mechanical Calculator › AC Size Calculator

AC Size Calculator

March 10, 2023 ·

AC Size Calculator

Find the cooling load and recommended air conditioner tonnage for a room, adjusted for room type, sun exposure, climate and occupancy, plus an estimated running cost.

Room Details

Room Type:
Sun / Window Exposure:
Climate Zone:

Occupancy load is added for occupants beyond the first 2, who are assumed to be included in the base figure.

Efficiency & Running Cost (Optional)

AC Star Rating:

Power input is estimated as Tonnage × the kW-per-TR figure for the selected star rating. Leave the price blank to skip the running cost estimate.

ROOM VOLUME
--m³
COOLING LOAD REQUIRED
--BTU/hr
COOLING LOAD (EXACT)
--TR
Tons of refrigeration, before rounding
RECOMMENDED AC SIZE
--TR
ESTIMATED POWER INPUT
--kW
RUNNING COST PER HOUR
--
RUNNING COST PER DAY
--
RUNNING COST PER MONTH
--
30 days
Note:
  • This is a quick-sizing estimate for a typical residential or office room. For a hall, an unusually high ceiling, a glass facade, or a commercial space, get a proper heat-load (cooling load) calculation done by an HVAC engineer.
  • 1 Ton of Refrigeration (TR) = 12,000 BTU/hr = 3.517 kW of cooling capacity.
  • Oversizing an AC causes short-cycling (frequent on/off) and poor humidity removal; undersizing means it runs continuously without reaching the set temperature. Always round up to the nearest standard size rather than down.

Reference Guide: Cooling Load Estimation

1. Base Cooling Load

Base Load (BTU/hr) = Floor Area (m²) × 269 × (Ceiling Height / 2.7 m)

269 BTU/hr per sq.m (about 25 BTU/hr per sq.ft) is a commonly used rule-of-thumb base rate for a reasonably well-insulated room with a standard 2.7 m (9 ft) ceiling; the height term scales this up or down for a taller or shorter room.

2. Adjustment Factors

Adjusted Load = Base Load × Room Type Factor × Sun Exposure Factor × Climate Factor
Total Load = Adjusted Load + [(Occupants − 2) × 600 BTU/hr] + (Equipment Watts × 3.412)

Each additional person beyond the first two adds roughly 600 BTU/hr of body heat and moisture load. Electronics, kitchen equipment and other heat sources are converted from watts to BTU/hr at 3.412 BTU/hr per watt.

3. Tonnage and Standard Sizes

Tons of Refrigeration (TR) = Total Load (BTU/hr) / 12,000

The calculated tonnage is rounded up to the nearest size commonly sold in India: 0.8, 1.0, 1.5, 2.0, 2.5, 3.0, 4.0 or 5.0 TR.

4. Typical Room Size to Tonnage (Quick Reference)

Room AreaTypical AC Size
Up to 10 sq.m (110 sq.ft)0.8 TR
10 – 14 sq.m (110 – 150 sq.ft)1.0 TR
14 – 23 sq.m (150 – 250 sq.ft)1.5 TR
23 – 37 sq.m (250 – 400 sq.ft)2.0 TR
37 – 56 sq.m (400 – 600 sq.ft)3.0 TR

5. Power Input and Running Cost

A 3-star split AC typically draws about 1.4–1.5 kW of electrical input per TR of cooling, a 4-star unit about 1.2–1.3 kW/TR, and a 5-star (or inverter) unit about 1.0–1.1 kW/TR, though exact figures vary by model; check the BEE label on the specific unit you are considering.

Power Input (kW) = Recommended Size (TR) × kW per TR (by star rating)
Running Cost per Hour = Power Input (kW) × Electricity Price per kWh
MEP

K K Kranti
Shares practical MEP calculators, checklists and design guides on MEP Analysis.